Mostrar registro simples

dc.contributor.advisorTorres, Ricardo Lobato, 1983-pt_BR
dc.contributor.otherUniversidade Federal do Paraná. Setor de Ciências Sociais Aplicadas. Curso de Graduação em Ciências Econômicaspt_BR
dc.creatorNascimento, Matheus Rover Rodrigues dopt_BR
dc.date.accessioned2024-09-16T19:42:40Z
dc.date.available2024-09-16T19:42:40Z
dc.date.issued2024pt_BR
dc.identifier.urihttps://hdl.handle.net/1884/89724
dc.descriptionOrientador: Prof. Dr. Ricardo Lobato Torrespt_BR
dc.descriptionMonografia (graduação) - Universidade Federal do Paraná, Setor de Ciências Sociais Aplicadas, Curso de Ciências Econômicaspt_BR
dc.descriptionInclui referênciaspt_BR
dc.description.abstractResumo : O presente trabalho tem por finalidade analisar a viabilidade econômica e financeira da instalação de uma usina fotovoltaica de geração distribuída no campus Jardim Botânico da Universidade Federal do Paraná, situado em Curitiba. A metodologia da análise foi baseada em etapas, combinando análises teóricas, qualitativas, quantitativas, regulatórias e de sensibilidade, seguindo referências de elaboração e análise de projetos (Blank, 2011). De início, realizou-se uma breve análise do sistema elétrico brasileiro e do contexto climático atual com o intuito de entender se as características do projeto seriam adequadas à infraestrutura atual do país e da região de instalação da usina. Em seguida, foram conduzidos estudos de mercado e de engenharia para verificar se o mercado, principalmente no âmbito público, é favorável a utilização de fontes de renováveis de energia em instituições públicas e se o projeto atende às normas técnicas, de materiais e requisitos mínimos de engenharia para sua concepção. Para a análise econômica e financeira, foram calculados indicadores de retorno do projeto como o valor presente líquido, fluxo de caixa, taxa interna de retorno e payback, considerando três diferentes cenários para a análise de sensibilidade. Os cenários considerados levaram em conta a taxa de desconto utilizada para o cálculo dos indicadores. No cenário otimista, considerou-se a taxa de desconto social do Instituto de Pesquisa Econômica Aplicada de 10% ao ano (IPEA, 2019). No cenário conservador, considerou-se a taxa de desconto de 14,25 a.a., baseada na taxa Selic mais alta dos últimos anos (Banco Central, 2024) e, por fim, no cenário pessimista, considerou-se a como taxa de desconto a taxa do cenário conservador mais um prêmio de risco de 5,75% a.a., fazendo com que a taxa utilizada neste cenário fosse de 20% ao anopt_BR
dc.description.abstractAbstract : The purpose of this study is to analyze the economic and financial feasibility of installing a distributed generation photovoltaic power plant at the Jardim Botânico campus of the Federal University of Paraná, located in Curitiba. The analysis methodology was based on several stages, combining theoretical, qualitative, quantitative, regulatory, and sensitivity analyses, following references for project development and analysis (Blank, 2011). Initially, a brief analysis of the Brazilian electrical system and the current climatic context was conducted to understand whether the project's characteristics would be suitable for the current infrastructure of the country and the region where the plant would be installed. Next, market and engineering studies were conducted to verify whether the market, especially in the public sector, is favorable to the use of renewable energy sources in public institutions and whether the project meets the technical standards, material requirements, and minimum engineering requirements for its conception. For the economic and financial analysis, return indicators such as net present value, cash flow, internal rate of return, and payback were calculated, considering three different scenarios for sensitivity analysis. The scenarios considered the discount rate used for calculating the indicators. In the optimistic scenario, a social discount rate of 10% per year from the Institute for Applied Economic Research was considered (IPEA, 2019). In the conservative scenario, a discount rate of 14.25% per year was considered, based on the highest Selic rate in recent years (Banco Central, 2024). Finally, in the pessimistic scenario, the discount rate of the conservative scenario plus a risk premium of 5.75% per year was considered, making the discount rate used in this scenario 20% per yearpt_BR
dc.format.extent1 recurso online : PDF.pt_BR
dc.format.mimetypeapplication/pdfpt_BR
dc.languagePortuguêspt_BR
dc.subjectGeraçao de energia fotovoltaicapt_BR
dc.subjectUniversidades e faculdadespt_BR
dc.subjectEstudos de viabilidadept_BR
dc.subjectResponsabilidade social da empresapt_BR
dc.titleAnálise de viabilidade : instalação de usina fotovoltaica no Campus Jardim Botânico da Universidade Federal do Paranápt_BR
dc.typeTCC Graduação Digitalpt_BR


Arquivos deste item

Thumbnail

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples