Mostrar registro simples

dc.contributor.advisorLoures, Danton Richlin da Rochapt_BR
dc.contributor.otherMatias, Jorge Eduardo Foutopt_BR
dc.contributor.otherUniversidade Federal do Paraná. Setor de Ciências da Saúde. Programa de Pós-Graduação em Clínica Cirúrgicapt_BR
dc.creatorPesarini, Aldopt_BR
dc.date.accessioned2023-02-16T15:38:57Z
dc.date.available2023-02-16T15:38:57Z
dc.date.issued2005pt_BR
dc.identifier.urihttps://hdl.handle.net/1884/81201
dc.descriptionOrientador: Prof. Dr. Danton Richlin da Rocha Lourespt_BR
dc.descriptionCoordenador: Prof. Dr. Jorge Eduardo Fouto Matiaspt_BR
dc.descriptionTese (doutorado) - Universidade Federal do Paraná, Setor de Ciências da Saúde, Programa de Pós-Graduação em Clínica Cirúrgica. Defesa: Curitiba, 2005pt_BR
dc.descriptionInclui referências: p. 86-94pt_BR
dc.description.abstractResumo: Foi construído um simulador de fadiga para próteses valvulares cardíaca, com os recursos próprios do Laboratório de Máquinas Térmicas da Universidade Federal do Paraná e materiais disponíveis no comércio local. Foi possível realizar ensaios com velocidades de até 2.540 ciclos por minuto. Com auxílio da estroboscopia é possível verificar o fechamento e a abertura totais, bem como as posições intermediárias. Foram obtidas, em escala, as curvas de pressão x tempo transprotéticas, obteve-se também fotografias e filmagens em vídeo das próteses nas posições aberta, intermediárias e fechada, bem como suas nuances frente às alterações de fluxo e pressão. Foi possível detectar, com a máquina em funcionamento, a ocorrência de problemas de fadiga nas referidas próteses após 42 milhões de ciclos. Os resultados obtidos foram compatíveis com as normas preconizadas e os resultados encontrados na literatura.pt_BR
dc.description.abstractAbstract: A fatigue simulator of cardiac valve prosthesis was constructed with Thermal Machines Laboratories from Paraná Federal University's resources and local commercial materials. Velocity until 2.540 cycles per minute is possible to do. With stroboscopic light helps is possible to verify the totally closed and opened positions and so the intermediary too. Curves trans prosthetics of pressure x time on scale, photography and video from opened, intermediary and closed positions of the prosthesis was obtained. Nuance in front of minimally changes in pressure and flow was possible to observe. Fatigue problems from the prosthesis with the machine running after 42 million cycles was possible to observe. The results obtained were in conformity with the recommended standards and results seen in specialized literature.pt_BR
dc.format.extent122f. : il. color., grafs.pt_BR
dc.format.mimetypeapplication/pdfpt_BR
dc.languagePortuguêspt_BR
dc.relationDisponível em formato digitalpt_BR
dc.subjectTesespt_BR
dc.subjectImplante de prótesept_BR
dc.subjectTecnologia medicapt_BR
dc.subjectPrótese valvular metálicapt_BR
dc.subjectSimulador de fadigapt_BR
dc.subjectCirurgiapt_BR
dc.titleSimulador de fadiga para teste de próteses valvulares cardíacaspt_BR
dc.typeTesept_BR


Arquivos deste item

Thumbnail

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples