    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Simulador de fadiga para teste de próteses valvulares cardíacas

    Thumbnail
    Visualizar/Abrir
    R - T - ALDO PESARINI.pdf (37.46Mb)
    Data
    2005
    Autor
    Pesarini, Aldo
    Metadata
    Mostrar registro completo
    Resumo
    Resumo: Foi construído um simulador de fadiga para próteses valvulares cardíaca, com os recursos próprios do Laboratório de Máquinas Térmicas da Universidade Federal do Paraná e materiais disponíveis no comércio local. Foi possível realizar ensaios com velocidades de até 2.540 ciclos por minuto. Com auxílio da estroboscopia é possível verificar o fechamento e a abertura totais, bem como as posições intermediárias. Foram obtidas, em escala, as curvas de pressão x tempo transprotéticas, obteve-se também fotografias e filmagens em vídeo das próteses nas posições aberta, intermediárias e fechada, bem como suas nuances frente às alterações de fluxo e pressão. Foi possível detectar, com a máquina em funcionamento, a ocorrência de problemas de fadiga nas referidas próteses após 42 milhões de ciclos. Os resultados obtidos foram compatíveis com as normas preconizadas e os resultados encontrados na literatura.
     
    Abstract: A fatigue simulator of cardiac valve prosthesis was constructed with Thermal Machines Laboratories from Paraná Federal University's resources and local commercial materials. Velocity until 2.540 cycles per minute is possible to do. With stroboscopic light helps is possible to verify the totally closed and opened positions and so the intermediary too. Curves trans prosthetics of pressure x time on scale, photography and video from opened, intermediary and closed positions of the prosthesis was obtained. Nuance in front of minimally changes in pressure and flow was possible to observe. Fatigue problems from the prosthesis with the machine running after 42 million cycles was possible to observe. The results obtained were in conformity with the recommended standards and results seen in specialized literature.
     
    URI
    https://hdl.handle.net/1884/81201
    Collections
    • Teses [130]

    DSpace software copyright © 2002-2022  LYRASIS
    Entre em contato | Deixe sua opinião
    Theme by 
    Atmire NV
     

     

    Navegar

    Todo o repositórioComunidades e ColeçõesPor data do documentoAutoresTítulosAssuntosTipoEsta coleçãoPor data do documentoAutoresTítulosAssuntosTipo

    Minha conta

    EntrarCadastro

    Estatística

    Ver as estatísticas de uso

    DSpace software copyright © 2002-2022  LYRASIS
    Entre em contato | Deixe sua opinião
    Theme by 
    Atmire NV