• Entrar
    Ver item 
    •   Página inicial
    • BIBLIOTECA DIGITAL: Teses & Dissertações
    • 40001016018P0 Programa de Pós-Graduação em Clínica Cirúrgica
    • Teses
    • Ver item
    •   Página inicial
    • BIBLIOTECA DIGITAL: Teses & Dissertações
    • 40001016018P0 Programa de Pós-Graduação em Clínica Cirúrgica
    • Teses
    • Ver item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Avaliação topográfica da dispersão de excitabilidade neural em implante coclear e sua correlação com a função de recuperação neural

    Thumbnail
    Visualizar/Abrir
    R - T - BETTINA CARVALHO.pdf (3.666Mb)
    Data
    2024
    Autor
    Carvalho, Bettina
    Metadata
    Mostrar registro completo
    Resumo
    Resumo: Os implantes cocleares (IC) são dispositivos eletrônicos para o tratamento da surdez neurossensorial severa a profunda, e permitem medidas objetivas da função neural nos pacientes implantados que podem auxiliar na programação do processador de fala do IC e na melhor compreensão do sistema auditivo. O objetivo desse trabalho foi avaliar as medidas de Dispersão de Excitabilidade Neural (SOE) com uso de IC, em pacientes implantados adultos e crianças, ao longo das diferentes regiões da cóclea (apical, medial e basal) por meio de diferentes eletrodos estimulados, e compará-las com a Telemetria de resposta neural (NRT) e Função de recuperação neural (REC), nas diferentes regiões. Tratou-se de estudo transversal, descritivo e prospectivo. A SOE, NRT e REC, foram avaliadas em indivíduos submetidos à cirurgia de IC, divididos em três grupos de acordo com o eletrodo estimulado na região da cóclea: apical, medial e basal. Foram avaliados 19 orelhas, de 16 pacientes. A análise dos dados mostrou diferenças significativas entre todas as medidas nas regiões da cóclea, exceto REC TAU, sendo que a diferença mais significativa foi na SOE mm entre região medial e apical. Concluiu-se que houve diferença significativa na medida da SOE nas diferentes regiões da cóclea, essa diferença foi mais importante na comparação da região apical com a medial, correlacionando-se com a REC
     
    Abstract: Cochlear implants (CI) are electronic devices for the treatment of severe to profound sensorineural deafness, and allow objective measurements of neural function in implanted patients that can assist in programming the CI's speech processor and better understanding the auditory system. The objective of this research was to evaluate Spread of excitation (SOE) in adult and child implanted patients, along different regions of the cochlea (apical, medial and basal) through different stimulated electrodes, and compare it with Neural response telemetry (NRT) and recovery function (REC). It was a Cross-sectional, descriptive and prospective study. The SOE, NRT and REC (evaluated through the function of the parameters T0, A and TAU) were evaluated in individuals undergoing CI surgery, divided into three groups according to the electrode stimulated in the cochlea region: apical, medial and basal. 19 ears were evaluated. Data analysis showed significant differences between all measurements in the cochlear regions, except REC TAU, with the most significant difference being in the SOE mm between the medial and apical regions. In conclusion, a significant difference was found in the measurement of SOE in different regions of the cochlea, this difference was more important when comparing the apical with the medial region, correlating to REC
     
    URI
    https://hdl.handle.net/1884/94495
    Collections
    • Teses [130]

    DSpace software copyright © 2002-2022  LYRASIS
    Entre em contato | Deixe sua opinião
    Theme by 
    Atmire NV
     

     

    Navegar

    Todo o repositórioComunidades e ColeçõesPor data do documentoAutoresTítulosAssuntosTipoEsta coleçãoPor data do documentoAutoresTítulosAssuntosTipo

    Minha conta

    EntrarCadastro

    Estatística

    Ver as estatísticas de uso

    DSpace software copyright © 2002-2022  LYRASIS
    Entre em contato | Deixe sua opinião
    Theme by 
    Atmire NV