Mostrar registro simples

dc.contributor.advisorBatista, Antoniopt_BR
dc.contributor.otherKowalczuk, Alexandrept_BR
dc.contributor.otherUniversidade Federal do Paraná. Setor de Ciências da Saúde. Curso de Especialização em Endodontiapt_BR
dc.creatorInvernici, Juliana de Mendonçapt_BR
dc.date.accessioned2025-12-30T18:30:44Z
dc.date.available2025-12-30T18:30:44Z
dc.date.issued2011pt_BR
dc.identifier.urihttps://hdl.handle.net/1884/41361
dc.descriptionOrientador : Prof. Antonio Batistapt_BR
dc.descriptionCoorientador: Prof. Alexandre Kowalkzukpt_BR
dc.descriptionMonografia (especialização) - Universidade Federal do Paraná, Setor de Ciências da Saúde, Curso de Especialização em Endodontiapt_BR
dc.descriptionInclui referênciaspt_BR
dc.description.abstractResumo: A presente pesquisa teve por finalidade avaliar, "ex vivo"’, a eficácia dos localizadores foraminais eletrônicos Smarpex, Root ZX II e Romiapex A-15 na determinação do comprimento do canal radicular até o forame apical comparando-os com a real media de trabalho até o forame apical em dentes extraídos. Para tal foram utilizados 15 pré-molares humanos uniradiculares, com rizogênese completa e sem sinais de fratura apical. Após acesso coronário e radicular com brocas de Gates-Glidden # 1, 2 e 3, limas tipo K # 15 foram introduzidas no interior do canal radicular até a ponta ser visível na constrição apical sob auxílio do microscópio clínico com aumento de 20X. O comprimento de trabalho foi anotado e os dentes inseridos em um recipiente plástico contendo esponja floral embebida em solução fisiológica, e verificado qual comprimento cada aparelho acusava quando marcava o ponto zero. Os dados foram anotados e os resultados submetidos á análise estatística de Kuskal-Wallis ANOVA adotando-se variação de 0,05% (p>0,05). Os resultados mostraram que o aparelho Root ZX II foi mais preciso, porém sem diferença estatística significativa entre os outros aparelhos. Considerando-se uma variação de ±0,5mm, todos os aparelhos foram eficientes em 100% das amostras em localizar o forame apicalpt_BR
dc.description.abstractAbstract: The aim of this study was to evaluate, "ex vivo", the mensurement efficiency of the apex locator SmarPex, Root ZX II and Romiapex A-15, in the meansurement of the root canal length until the apical foramen comparing with the real length of the root canal until the apical foramen. For this, 15 extract human single mandibular premolars presenting complete root formation and no signs of apical fracture were selected. After coronal access and preflaring using the Gattes-Glidden drills # 1, 2 and 3, a # 15 K-file were insert into the canal until its tip was visible at the apical constriction under a clinical microscope at 20X magnification. The length was recorded and the teeth were inserting into the plastic box container floral sponge soaked with saline solution, and the measurement of the working length wich each electronic foramen locator verified until its show the zero point. Data were recorded and the results submitted to statistical analysis of Kuskal-Wallis ANOVA by adopting a variation of 0.05% (p> 0.05). The results showed that the Root ZX II apex locator was more accurate, but not statistically significant differences were found among other devices. Considering a range of ± 0.5 mm, all the apex locators were effective in 100% of the samples in locating the apical foramenpt_BR
dc.format.extent1 recurso online : PDF.pt_BR
dc.format.mimetypeapplication/pdfpt_BR
dc.languagePortuguêspt_BR
dc.subjectEndodontiapt_BR
dc.titleAnálise "ex vivo" da capacidade de três localizadores foraminais eletrônicos em determinar a posição do forame apicalpt_BR
dc.typeTCC Especialização Digitalpt_BR


Arquivos deste item

Thumbnail

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples