• Entrar
    Ver item 
    •   Página inicial
    • BIBLIOTECA DIGITAL: Teses & Dissertações
    • 40001016077P6 Programa de Pós-Graduação em Ciência Animal
    • Dissertações
    • Ver item
    •   Página inicial
    • BIBLIOTECA DIGITAL: Teses & Dissertações
    • 40001016077P6 Programa de Pós-Graduação em Ciência Animal
    • Dissertações
    • Ver item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Biocompatibilidade de implante de poliamida em traqueia de coelho (Oryctolagus cuniculus)

    Thumbnail
    Visualizar/Abrir
    R - D - MARCOS PIAZZOLO.pdf (3.481Mb)
    Data
    2021
    Autor
    Piazzolo, Marcos, 1983-
    Metadata
    Mostrar registro completo
    Resumo
    Resumo: O colapso traqueal é uma desordem comum quando se trata de alterações respiratórias de cães de raças pequenas e miniaturas. A afecção apresenta caráter progressivo e pode ser congênita ou adquirida. Para graus de colapso severos o implante de prótese que sustente o formato tubular da traqueia é o tratamento mais indicado. Atualmente o implante de prótese traqueal helicoidal extraluminal de nitinol é o tratamento de melhor resultado, porém o alto custo da prótese ainda é um empecilho na aplicação da técnica. O objetivo do trabalho foi averiguar a biocompatibilidade em modelo experimental (coelho) de prótese helicoidal extraluminal de poliamida modelada em impressora 3D. Para isso foram estudados 40 coelhos distribuídos em dois grupos e 4 blocos de tempos experimentais de 7, 14, 21 e 30 dias com 10 pacientes agrupados em cada bloco, sendo cinco para tratamento e cinco para controle em cada bloco. Vinte coelhos passaram por todo o processo cirúrgico sem receber a prótese (grupo controle - 7, 14, 21 e 30 dias) e outros 20 coelhos receberam a prótese (grupo tratamento - 7, 14, 21 e 30 dias). Após o período de acompanhamento as amostras de traqueia de cada grupo foram colhidas para exame histopatológico quanto a alterações de congestão, edema, fibrose, hemorragia, inflamação e necrose; Apenas um coelho apresentou deiscência. A maioria das amostras traqueais analisadas microscopicamente apresentaram alterações leves a moderadas quanto aos aspectos de biocompatibilidade, no entanto não houve diferença entre os grupos que receberam a prótese dos grupos que não receberam. Com base nos resultados obtidos concluise que a prótese traqueal helicoidal extraluminal confeccionada em poliamida por meio da impressão em três dimensões nas características utilizadas nesse trabalho provoca leve a moderada reação tecidual sendo considerada biocompatível.
     
    Abstract: Tracheal collapse is a common disorder when it comes to respiratory disorders in small and miniature breed dogs. The condition has a progressive character and can be congenital or acquired. For severe degrees of collapse, the implantation of a prosthesis that supports the tubular shape of the trachea is the most indicated treatment. Currently, the implant of nitinol extraluminal helical tracheal prosthesis is the treatment with the best results, but the high cost of the prosthesis is still an obstacle in the application of the technique. The objective of this work was to investigate the biocompatibility in an experimental model (rabbit) of an extraluminal helical polyamide prosthesis modeled on a 3D printer. For this, 40 rabbits were studied, divided into two groups and 4 blocks of experimental times of 7, 14, 21 and 30 days with 10 patients grouped in each block, being five for treatment and five for control in each block. Twenty rabbits underwent the entire surgical process without receiving the prosthesis (control group - 7, 14, 21 and 30 days) and another 20 rabbits received the prosthesis (treatment group - 7, 14, 21 and 30 days). After the follow-up period, trachea samples from each group were collected for histopathological examination for changes in congestion, edema, fibrosis, hemorrhage, inflammation and necrosis; Only one rabbit showed dehiscence. Most of the microscopically analyzed tracheal samples showed mild to moderate changes regarding biocompatibility aspects, however there was no difference between the groups that received the prosthesis and the groups that did not. Based on the results obtained, it is concluded that the extraluminal helical tracheal prosthesis made of polyamide by means of three-dimensional printing in the characteristics used in this work causes mild to moderate tissue reaction and is considered biocompatible.
     
    URI
    https://hdl.handle.net/1884/73788
    Collections
    • Dissertações [147]

    DSpace software copyright © 2002-2022  LYRASIS
    Entre em contato | Deixe sua opinião
    Theme by 
    Atmire NV
     

     

    Navegar

    Todo o repositórioComunidades e ColeçõesPor data do documentoAutoresTítulosAssuntosTipoEsta coleçãoPor data do documentoAutoresTítulosAssuntosTipo

    Minha conta

    EntrarCadastro

    Estatística

    Ver as estatísticas de uso

    DSpace software copyright © 2002-2022  LYRASIS
    Entre em contato | Deixe sua opinião
    Theme by 
    Atmire NV