Mostrar registro simples

dc.contributor.advisorMiranda, Leonardo Fagundes Rosemback, 1975-pt_BR
dc.contributor.otherGomes, Márcio Henrique de Avelarpt_BR
dc.contributor.otherUniversidade Federal do Paraná. Setor de Tecnologia. Programa de Pós-Graduação em Engenharia Civilpt_BR
dc.creatorFranzen, Fabiani Pereirapt_BR
dc.date.accessioned2024-06-05T12:58:47Z
dc.date.available2024-06-05T12:58:47Z
dc.date.issued2015pt_BR
dc.identifier.urihttps://hdl.handle.net/1884/41973
dc.descriptionOrientador: Prof. Dr. Leonardo Fagundes Rosemback Mirandapt_BR
dc.descriptionCoorientador: Prof. Dr. Márcio Henrique de Avelar Gomespt_BR
dc.descriptionDissertação (mestrado) - Universidade Federal do Paraná, Setor de Tecnologia, Programa de Pós-Graduação em Construção Civil. Defesa: Curitiba, 20/01/2016pt_BR
dc.descriptionInclui referências : f. 136-141pt_BR
dc.descriptionÁrea de concentração: Materiais e estruturaspt_BR
dc.description.abstractResumo: A construção civil no Brasil necessita de uma reformulação para atender a crescimento populacional. Uma alternativa é a utilização de tecnologias com características industrializadas como o "light steel framing" (LSF) que é um sistema aberto, modular, de rápida execução, fácil manutenção e sustentável. Com a vigência da norma de desempenho, a NBR 15575 (ABNT, 2013), nasce uma necessidade de ciência sobre o desempenho dos sistemas. Materiais com características sustentáveis e de menor custo precisam ser avaliados de forma a contribuir para o avanço sustentável do LSF no Brasil, então o objetivo é avaliar o desempenho de alternativas para as vedações verticais externas em LSF com relação ao seu desempenho térmico e acústico visando menor custo e sustentabilidade. Os painéis possuem elementos constantes e variáveis como os isolantes e as massas para acabamento. Foram testados produtos industrializados, resíduo industrial, gesso acartonado moído e em pedaços (resíduo da construção) e materiais utilizados em outros sistemas construtivos. O desempenho térmico foi analisado segundo o procedimento 1A Simplificado - NBR 15575 (ABNT, 2013) e experimento onde comparou-se a diferença de temperatura com a medição da face interna enquanto que uma fonte de calor manteve a temperatura da face externa em 80oC por 60 minutos. O desempenho acústico foi analisado utilizando o método da função de transferência, já que os materiais reciclados não possuem índices para incrementar os cálculos ou simulações nos dois casos. Os resultados obtidos foram analisados pelo Processo de Análise Hierárquica (AHP) que determinou qual é o melhor painel. Quando o desempenho térmico é considerado o critério de maior importância, os painéis com acabamento na face externa (estuque sintético), massa látex PVA na parte interna e no interior do painel fibra cerâmica obtiveram o melhor desempenho. Para o desempenho acústico, o painel com lã de vidro no miolo obteve o melhor desempenho e quando o critério de maior relevância é o custo, os painéis com o interior preenchido com materiais reciclados obtiveram o menor valor.pt_BR
dc.description.abstractAbstract: Civil construction in Brazil needs a reformulation to attend the population growth. One of the options is the use of technologies with industrialized characteristics, such as "light steel frame"(LSF) which is an open system, modular, of fast execution, easy maintenance and sustainable. With the legality of the law performance , the NBR 15575(ABNT, 2013), the need of a study over the system's performance is born. Covering, isolation and finishing with sustainable characteristics and of low cost need to be appraised in a way to contribute to the sustainable advance of LSF in Brazil, therefore the goal is to evaluate the alternatives of performance for external vertical sealing in LSF with regards to its thermal performance and acoustic looking for low cost and sustainability. The frames have constant elements and changeable, like insulating materials and finishing batters. Were tested industrialized products such as glass wool and rock wool, ceramic fiber(industrial residue), crushed wall plaster(drywall) and in pieces(construction residues) and the acoustic stripe. the thermal performance was analysed according to procedure 1 A Simplified - NBR 15575 (ABNT, 2013) and the experiment, as well the acoustic performance that used the transfer function method, since the recycled materials do not have contents to increase the calculations or simulations. Were realized in sites with easy control of climate variables. In the thermal experiment measurements were done in one face, while the other source of heat kept the temperature from the opposite face in 80 C (176 F) for 60 minutes. The obtained results were analyzed by the Analytic Hierarchy (A.H.P.) that settled which is the best panel. When thermal performance is considered the criterion of biggest importance, the panels with synthetic stucco on the external face, PVA latex on the internal part and in the core ceramic fiber, obtained the best performance. For the acoustic performance, the panel with glass wool in the core obtained the best performance and when the criterion of relevancy is cost, the filled core panels with recycled material had the lowest cost.pt_BR
dc.format.extent141 p. : il. algumas color.pt_BR
dc.format.mimetypeapplication/pdfpt_BR
dc.languagePortuguêspt_BR
dc.relationDisponível em formato digitalpt_BR
dc.subjectEngenharia Civilpt_BR
dc.subjectAço - Estruturaspt_BR
dc.subjectVentilaçãopt_BR
dc.subjectAcústica arquitetônicapt_BR
dc.titleAnálise do desempenho térmico e acústico de vedações verticais externas executadas em light steel framingpt_BR
dc.typeDissertaçãopt_BR


Arquivos deste item

Thumbnail

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples