Mostrar registro simples

dc.contributor.advisorMannich, Michael, 1984-pt_BR
dc.contributor.otherUniversidade Federal do Paraná. Setor de Tecnologia. Programa de Pós-Graduação em Engenharia Ambientalpt_BR
dc.creatorGabriel, Pedro G.pt_BR
dc.date.accessioned2023-05-26T18:41:39Z
dc.date.available2023-05-26T18:41:39Z
dc.date.issued2023pt_BR
dc.identifier.urihttps://hdl.handle.net/1884/82911
dc.descriptionOrientador: Michael Mannichpt_BR
dc.descriptionDissertação (mestrado) - Universidade Federal do Paraná, Setor de Tecnologia, Programa de Pós-Graduação em Engenharia Ambiental. Defesa : Curitiba, 31/01/2023pt_BR
dc.descriptionInclui referências: p. 55-64pt_BR
dc.description.abstractResumo: Este documento discorre sobre o desenvolvimento de um equilibrador do tipo marble, para monitoramento de gases dissolvidos em água. A montagem constitui no uso de sensores de temperatura da água e gás carbônico, cujo objetivo é de realizar o monitoramento desses parâmetros em água com alta frequência temporal. Os sensores utilizados foram o K30 para medição da concentração de CO2 e DS18D20 para temperatura da água. O sistema foi montado utilizando a plataforma Arduino como controlador e outros componentes eletrônicos, sendo realizados testes em ambiente de laboratório e em campo, para identificar as limitações do equipamento, bem como o aperfeiçoamento da montagem e consumo de energia do equipamento. Os resultados das medições foram comparados com a titulação de alcalinidade bem como com a Lei de Henry, obtendo erros abaixo de 5,5% e sugerem que a estratégia adotada pode servir como guia para estudos similares no Brasil, já que muitas vezes os custos desse tipo de monitoramento são impeditivos.pt_BR
dc.description.abstractAbstract: This document discusses the development of a marble-type equilibrator for monitoring dissolved gases in water. The assembly uses water and carbon dioxide temperature sensors, whose objective is to monitor these parameters in water with a high temporal frequency. The sensors used were the K30 to measure the CO2 concentration and the DS18D20 to measure the water temperature. The system was assembled using the Arduino platform as a controller and other electronic components, with tests being carried out in a laboratory environment and in the field to identify the limitations of the equipment as well as the improvement of assembly and energy consumption of the equipment. The results of the measurements were compared with the alkalinity titration as well as with Henry's Law, obtaining errors below 5.5%, suggesting that the adopted strategy can serve as a guide for similar studies in Brazil since many times the costs of this type of monitoring are impeditive.pt_BR
dc.format.extent1 recurso online : PDF.pt_BR
dc.format.mimetypeapplication/pdfpt_BR
dc.languagePortuguêspt_BR
dc.subjectEngenharia ambientalpt_BR
dc.subjectGases estufapt_BR
dc.subjectMarmorept_BR
dc.subjectInstrumentos de mediçãopt_BR
dc.subjectEngenharia Sanitáriapt_BR
dc.titleDesenvolvimento de equilibrador para medição de gás CO2 dissolvido em águapt_BR
dc.typeDissertação Digitalpt_BR


Arquivos deste item

Thumbnail

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples