Mostrar registro simples

dc.contributor.advisorOta, José Junji, 1951-pt_BR
dc.contributor.authorMerida, Luis Mauricio Romeropt_BR
dc.contributor.otherBleninger, Tobias Bernward, 1972-pt_BR
dc.contributor.otherUniversidade Federal do Paraná. Setor de Tecnologia. Programa de Pós-Graduação em Engenharia de Recursos Hídricos e Ambientalpt_BR
dc.date.accessioned2021-06-17T19:25:06Z
dc.date.available2021-06-17T19:25:06Z
dc.date.issued2020pt_BR
dc.identifier.urihttps://hdl.handle.net/1884/69989
dc.descriptionOrientador: Prof. Dr. José Junji Otapt_BR
dc.descriptionCoorientador: Prof. Dr. Tobias Bleningerpt_BR
dc.descriptionTese (doutorado) - Universidade Federal do Paraná, Setor de Tecnologia, Programa de Pós-Graduação em Engenharia de Recursos Hídricos e Ambiental. Defesa : Curitiba, 27/08/2020pt_BR
dc.descriptionInclui referências: p. 151-161pt_BR
dc.description.abstractResumo: O objetivo do presente trabalho de pesquisa é avaliar o efeito de ejeção em uma usina hidrelétrica de baixa queda com descarregadores de fundo laterais. Como abordagem inicial, o estudo inclui dez variantes geométricas, sob condições submersas a jusante usando testes de modelo em escala 1:70. Os resultados do teste modelo são comparados com equações teóricas da literatura científica, e novas equações são propostas para avaliar os efeitos da ejeção. Todas as variantes consistem em três turbinas Kaplan verticais, quatro conduítes laterais inferiores, uma rampa e dois pilares laterais em direção ao canal principal. Vazões constantes de água através das turbinas e condutos laterais, bem como as elevações do escoamento a montante e a jusante da usina, foram calibradas por meio de 122 testes de modelo sob condições submersas a jusante. As alturas de pressão na parte inferior das saídas dos tubos de sucção das turbinas foram medidas usando 10 piezômetros para avaliar o efeito de ejeção total e o ganho de carga das turbinas. As velocidades de escoamento foram medidas em diferentes elevações no modelo por meio de um Velocímetro Doppler Acústico (ADV). As novas equações teóricas calibradas produziram resultados notavelmente consistentes para a avaliação da ejeção efetiva de 537 cenários hipotéticos de escoamento. Como segunda abordagem, três modelos empíricos que relacionam a ejeção efectiva medida com parâmetros adimensionais de escoamento, submersão e turbulência foram obtidos e validados em 28 cenários de escoamento. Os resultados mostram que os parâmetros de turbulência avaliados têm pouca ou nenhuma influência na ejeção efetiva observada. A taxa entre as vazões turbinada e dos condutos laterais, a submersão do escoamento e o número de Froude nas saídas dos dutos laterais são as variáveis relevantes. No estagio final, foram encontradas duas relações empíricas entre o efeito ejetor efetivo e a potência e o rendimento da turbina respeitivamente, para a alternativa com as maiores vazões testadas , incluindo as curvas de colina das turbinas Kaplan no esquema de cálculo do seu modelo teórico, além de uma avaliação do incremento da potencia e rendimento unitários do sistema. Palavras-chave: Efeito ejetor. Usina hidrelétrica de baixa queda. Descargas de fundo. Condição de fluxo submerso. Turbulência. Potência e rendimento.pt_BR
dc.description.abstractAbstract: The aim of the present research work is to assess the ejection effect in a low-head hydropower plant with lateral conduits. The study includes ten geometrical variants, under submerged downstream condition using 1:70 scale models tests. As an initial approach, the model test results are compared to theoretical equations from the scientific literature, and new equations are proposed to assess ejection effects. All variants consist of three vertical Kaplan turbines, four lateral bottom conduits, an apron and two lateral piers towards the main channel. Steady water discharges through the turbines and lateral conduits, as well as flow elevations upstream and downstream the plant, were calibrated by means of 122 model tests under submerged downstream conditions. Pressure heights at the bottom of the turbine draft tube outlets were measured using 10 piezometers to assess the total ejection effect and the gain of head due to the turbines. Flow velocities were measured at different elevations in the model by means of an Acoustic Doppler Velocimeter (ADV). The new theoretical calibrated equations produced remarkably consistent results for the effective ejection assessment from 537 hypothetical flow scenarios. As a second approach, three empirical models relating the measured ejection effect to flow, submergence and turbulence dimensionless parameters, were obtained and validated from 28 flow scenarios. Results show that the assessed turbulence parameters have little or no influence at all on the observed effective ejection. In this approach, the discharge rate between the turbines and the bottom lateral conduits, flow submergence and the Froude number at the conduits outlets are the key relevant variables, hence, reinforcing the results obtained from the initial approach. As a final step, two empirical relationships between effective ejection effect and turbine power and efficiency were found respectively for the alternative with the highest discharges tested, through the use of the provided power-efficiency curves for the Kaplan turbines, within the calculating scheme for its theoretical model. in addition to an evaluation of the increase of the unitary power and efficiency. Key words: Ejection effect. Low-head hydroelectric powerplant. Lateral conduits. Submerged flow condition. Turbulence. Turbine power and efficiencypt_BR
dc.format.extent1 arquivo (178 p.) : il. (algumas color.).pt_BR
dc.format.mimetypeapplication/pdfpt_BR
dc.languagePortuguêspt_BR
dc.subjectUsinas hidreletricaspt_BR
dc.subjectTurbulênciapt_BR
dc.subjectRecursos hídricospt_BR
dc.titleAproveitamento do efeito ejetor em usina hidrelétrica de baixa queda por meio de condutos laterais em condição submersapt_BR
dc.typeTese Digitalpt_BR


Arquivos deste item

Thumbnail

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples