    Análise de especificações de aterro e correlação entre CBR e capacidade de carga em solos compactados

    Thumbnail
    Visualizar/Abrir
    R - D - IDA AGNER DE FARIA MILLEO.pdf (9.352Mb)
    Data
    2012
    Autor
    Milléo, Ida Agner de Faria
    Metadata
    Mostrar registro completo
    Resumo
    Resumo: Parâmetros de controle tais como teor de umidade e valores de CBR foram estabelecidos em obras de subestação de energia, com objetivo de assegurar capacidade de suporte e recalques adequados de aterros. O CBR mínimo adotado, igual a 10%, foi tomado como aceitável e diversas obras realizadas nos últimos anos têm demonstrado bom desempenho. O objetivo do presente estudo foi verificar a pertinência de tais parâmetros especificados, por meio de testes de campo (provas de carga sobre placa) e em laboratório (cisalhamento direto, adensamento, CBR e caracterização do solo), focando aterros executados em alguns locais do Estado do Paraná. Tentativas de correlacionar os valores de CBR com alguns parâmetros geotécnicos mais representativos de capacidade de suporte foram feitas e conclusões são apresentadas, mostrando tendências razoáveis entre CBR e coeficiente de recalque, por exemplo, em especial para solos mais arenosos.
     
    Abstract: Some common geotechnical parameters, such as water content and CBR value, were tentatively established to help provide adequate support and settlement fill behavior for electric substation structures. A minimum CBR adopted by an electric power company, equal to 10%, has been used for some time and was checked in real works. The objective of the present study was to verify the correctness of such simple specification by means of field plate load tests and laboratory tests (consolidation, direct shear, compaction, CBR and soil characterization), emphasizing such structures built in a few sites around Paraná State. Attempts to correlate CBR values with other considered more representative geotechnical parameters of fills were made and some conclusions are presented, showing so far reasonable tendency between CBR and deformation modulus, as well as with bearing capacity, for example, mainly for sandy soils.
     
    URI
    https://hdl.handle.net/1884/29030
    Collections
    • Teses & Dissertações [10894]

    DSpace software copyright © 2002-2022  LYRASIS
    Entre em contato | Deixe sua opinião
    Theme by 
    Atmire NV
     

     

    Navegar

    Todo o repositórioComunidades e ColeçõesPor data do documentoAutoresTítulosAssuntosTipoEsta coleçãoPor data do documentoAutoresTítulosAssuntosTipo

    Minha conta

    EntrarCadastro

    Estatística

    Ver as estatísticas de uso

    DSpace software copyright © 2002-2022  LYRASIS
    Entre em contato | Deixe sua opinião
    Theme by 
    Atmire NV