Mostrar registro simples

dc.contributor.advisorPawlowsky, Urivald, 1940-pt_BR
dc.contributor.otherUniversidade Federal do Paraná. Setor de Tecnologia. Programa de Pós-Graduação em Engenharia de Recursos Hídricos e Ambientalpt_BR
dc.creatorBusato, Rosiletept_BR
dc.date.accessioned2024-07-22T18:47:32Z
dc.date.available2024-07-22T18:47:32Z
dc.date.issued2004pt_BR
dc.identifier.urihttps://hdl.handle.net/1884/1589
dc.descriptionOrientador: Urivald Pawlowskypt_BR
dc.descriptionInclui apêndicept_BR
dc.descriptionDissertação (mestrado) - Universidade Federal do Paraná, Setor de Tecnologia, Programa de Pós-Graduação em Recursos Hídricos e Ambientais. Defesa: Curitiba, 2004pt_BR
dc.descriptionInclui bibliografiapt_BR
dc.description.abstractResumo: O processo anaeróbio de tratamento de esgoto doméstico através de reator anaeróbio de fluxo ascendente e manta de lodo (UASB) vem sendo amplamente utilizados no Paraná, Brasil,e em outros estados brasileiros. Esse processo apresenta, no aspecto teórico, algumas vantagens quando comparado ao processo aeróbio. Entre estas as principais são a menor produção de lodo, a formação do gás metano, que é um subproduto com potencialidade de aproveitamento, e o menor custo de instalação e operação do sistema. Apesar das vantagens descritas, os reatores anaeróbios geralmente necessitam de uma etapa de pós-tratamento dos efluentes para atender ao srequisitos da legislação ambiental e preservar o meio ambiente. Neste sentido a Companhia de Saneamento do Paraná — SANEPAR, vem utilizando o filtro anaeróbio de fluxo ascendente (FA) como pós-tratamento de reator UASB. Visando a avaliação dos critérios de dimensionamento e projeto desse sistema, este trabalho estudou o desempenho de um filtro anaeróbio operando sob condições reais de utilização. Para tanto foi monitorado um sistema de tratamento de esgoto doméstico na cidade de Imbituva, no estado do Paraná, composto por gradeamento manual, desarenador, reator UASB com volume de 300 m3 e filtro anaeróbio de fluxo ascendente com volume total de 681 m3 e volume útil de 453,95 m3. Após trinta e uma semanas de monitoramento o sistema UASB/FA apresentou resultados médios de remoção de DQO total de 72%, com remoção média no FA de 29%, resultando em concentração efluente média de DQO total de 166,61 mg/L. Para eficiência de remoção de DBO total os resultados foram de 78% para média global, onde para o FA a remoção média foi de 26%, com concentração efluente média de DQO total de 47 mg/L. A concentração média global de SST no efluente final foi de 80 mg/L, resultando em uma eficiência global do sistema de 71%, com remoção média de 37% no FA. Pelos resultados encontrados, verifica-se que o FA é uma alternativa viável para polimento dos efluentes de reatores UASB. pt_BR
dc.description.abstractAbstract:  The anaerobic domestic sewage treatment process through an up-flowanaerobic sludge blanket reactor (UASB) has been widely used in the State ofParana, Brazil, and in other Brazilian States. This process presents, theoretically, some advantages when compared to the aerobic process. Among such advantages the main ones are the smaller production of sludge, the formation of methane gas, which is a sub product with utilization potential, and the lower cost of installation and operation of the system. Despite the advantages described, the anaerobic reactors usually need a stage of post-treatment of the effluents to attend the requirement of the environmental legislation and to preserve the environment. For such cases SANEPAR (the Sanitation Company of Parana State) have been using the anaerobic up-flow filter as post-treatment of UASB reactor. Aiming the evaluation of the dimensioning and project of such criteria, the present work evaluated the performance of anaerobic filter that operated under real conditions of utilization. Therefore a system of domestic treatment was monitored in Imbituva town, Parana State, composed of a manually cleaned bar screen, channels for grit removal, one UASB type reactor with 300 m' useful capacity and an up-flow anaerobic filter with total volume of681 m3 and useful capacity of 453.95 m3. After thirty one weeks of monitoring, the system UASB/FA presented average results for total COD removal of72%, with average removal in the FA of 29%,resulting in the average concentration of effluent of total COD of 166.61 mg/L. For the efficiency of total BOD removal, the results were of 78% for the global average, where for FA the average removal was 26% and the final plant effluen thad an average concentration of 47 mg/L. For total SS the results of efficiency removal was 71% and the final plant had an average concentration of 80mg/Lwith average removal of37 % in the FA. By the results found, it can be verified that the FA is an alternative for the polishing of the of UASB reactor effluent. pt_BR
dc.format.extentxxiii, 214f. : il. algumas color., grafs., tabs.pt_BR
dc.format.mimetypeapplication/pdfpt_BR
dc.languagePortuguêspt_BR
dc.relationDisponível em formato digitalpt_BR
dc.subjectÁguas residuaispt_BR
dc.subjectEsgotospt_BR
dc.subjectFiltro e filtraçaopt_BR
dc.subjectRecursos Hídricospt_BR
dc.titleDesempenho de um filtro anaeróbio de fluxo ascendente como tratamento de efluente de reator UASB : estudo de caso da ETE de Imbituvapt_BR
dc.typeDissertaçãopt_BR


Arquivos deste item

Thumbnail

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples