• Login
    View Item 
    •   DSpace Home
    • BIBLIOTECA DIGITAL: Teses & Dissertações
    • 40001016002P6 Programa de Pós-Graduação em Ciências Geodésicas
    • Dissertações
    • View Item
    •   DSpace Home
    • BIBLIOTECA DIGITAL: Teses & Dissertações
    • 40001016002P6 Programa de Pós-Graduação em Ciências Geodésicas
    • Dissertações
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Calibraçao de câmaras fotogramétricas : aplicaçao dos métodos: câmaras convergentes e campos mistos

    Thumbnail
    View/Open
    D - MARY ANGELICA DE AZEVEDO OLIVAS.pdf (2.214Mb)
    Date
    1980
    Author
    Olivas, Mary Angelica de Azevedo, 1951-
    Andrade, Jose Bittencourt de, 1937-
    Metadata
    Show full item record
    Subject
    Calibração
    Teses
    Geodesia
    xmlui.dri2xhtml.METS-1.0.item-type
    Dissertação
    Abstract
    Resumo: Calibração de câmaras fotogramétricas é ainda hoje, no Brasil, um tema pouco considerado pelos fotogrametristas. O presente trabalho possui como finalidade principal, apresentar alguns resultados obtidos com a aplicação de dois métodos· de campo específicos para calibração de câmaras: - MÉTODO DOS CAMPOS MISTOS - MÉTODO DAS CÂMARAS CONVERGENTES. Visto que não foi possível a aplicação dos métodos em câmaras reais, procuramos através de fotografias sintéticas, uma máxima aproximação de situações concretas. Como pode ser verificado pelos resultados alcançados, os métodos são eficientes e podem, sem muitas dificuldades, preencher a lacuna deixada pela falta de calibração de câmaras na fotogrametria brasileira.
     
    Abstract: At the present time, the calibration of cameras is an activity that has been given little consideration by the photogrammetrists of Brazil. The main purpose of this dissertation is to present some results which were obtained from the application of two specific methods of camera calibration. These methods were: Method of Mixed Ranges Self-calibration method. Because it was not possible to apply these methods to actual cameras, an attempt was made to give a good approximation to real situations by creating digitally simulated photographs. The results that were obtained showed that both methods are satisfactory, and therefore that both could be used to fill the gap left by the lack of camera calibration in Brazil.
     
    URI
    http://hdl.handle.net/1884/37208
    Collections
    • Dissertações [301]

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsxmlui.ArtifactBrowser.Navigation.browse_typeThis CollectionBy Issue DateAuthorsTitlesSubjectsxmlui.ArtifactBrowser.Navigation.browse_type

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV