Mostrar registro simples

dc.contributor.advisorFroehner, Sandro, 1970-pt_BR
dc.contributor.otherSantos, Manoelpt_BR
dc.contributor.otherUniversidade Federal do Paraná. Setor de Tecnologia. Programa de Pós-Graduação em Engenharia Ambientalpt_BR
dc.creatorShahateet, Kaian Fernandespt_BR
dc.date.accessioned2024-04-08T17:05:39Z
dc.date.available2024-04-08T17:05:39Z
dc.date.issued2018pt_BR
dc.identifier.urihttps://hdl.handle.net/1884/56158
dc.descriptionOrientador: Prof. Dr. Sandro Froehnerpt_BR
dc.descriptionCoorientador: Prof Dr. Manoel Santospt_BR
dc.descriptionDissertação (mestrado) - Universidade Federal do Paraná, Setor de Tecnologia, Programa de Pós-Graduação em Engenharia Ambiental. Defesa : Curitiba, 16/05/2018pt_BR
dc.descriptionInclui referências: p.73-75pt_BR
dc.description.abstractResumo: A questao do saneamento basico no Brasil ainda e de fundamental importancia, com isso, o presente trabalho busca propor uma comparacao entre o metodo de tratamento utilizando-se de autoctones microbianos e sistemas de tratamento de esgoto sanitario convencionais. Para esta finalidade, foi selecionada uma estacao de tratamento de esgoto em uma cidade de 12.000 habitantes, com 98% da populacao atendida por tratamento de esgoto no estado de Sao Paulo com sistema de lagoas (lagoa anaerobia seguida de lagoa facultativa aerada) e um sistema fossa-filtro (fossa-septica seguida por filtro anaerobio) em um distrito da mesma cidade atendendo uma populacao de 320 habitantes. Os autoctones microbianos foram selecionados e separados em um laboratorio e posteriormente introduzidos no sistema de tratamento das ETE's a cada 24h. O desempenho e eficiencia dos sistemas de tratamento foi acompanhado pela analise de parametros tradicionais como DBO, DQO, solidos sedimentaveis e pH, avaliados na condicao de pre durante e pos tratamento. O sistema de lagoas apresentou manutencao nos valores de remocao de DBO, DQO e pH (eficiencia media de remocao de DBO em torno de 81,20%, DQO de 73,62% e pH em 7,6); reducao nos valores de solidos sedimentaveis (de 1,39 para 0,11 mL/L) e oxigenio dissolvido (de 0,2 para 0,07 mg/L) mesmo apos o desligamento dos aeradores, o que proporcionou uma reducao nos custos estimados em R$: 9.852 comparando os periodos sem e com a bioadicao. O sistema fossa-filtro apresentou um aumento na eficiencia de remocao de DBO e DQO (de 64,68 para 83,99%; e 58,48% para 80,14%, respectivamente), manutencao do pH (7,6) e reducao dos solidos sedimentaveis (de 1,38 para 0,23 mL/L).pt_BR
dc.description.abstractAbstract: The issue of sanitation in Brazil still of fundamental importance, with this, the present work seeks to propose a comparison between the residual water treatment method using autochtonous microbes and conventional sewage treatment systems. For this purpose, a sewage treatment plant was selected in a city of 12,000 inhabitants, with 98% of the population served by sewage treatment in the state of São Paulo with ponds system (anaerobic ponds followed by facultative ponds) and a system tank-filter (septic tank followed by anaerobic filter) in a district of the same city serving a population of 320 inhabitants. The autochthonous microbes were selected and separated in a laboratory of a biotechnology company and introduced in the sewage treatment systems erevy 24h. The performance and efficiency of the treatment systems was accompanied by the analysis of traditional parameters such as BOD, COD, sedimentable solids and pH, evaluated before, during and after the bioaumentation treatment. The system of ponds showed maintenance in the values of BOD, COD and pH (average efficiency of removal of BOD around 81.20%, COD of 73.62% and pH of 7.6); reduction in sedimentable solids (from 1.39 to 0.11 mL/L) and dissolved oxygen (from 0.2 to 0.07 mg/L) even after the aerators were shut down, which led to a reduction in estimated costs in R $: 9,852 comparing the periods without and with the bioaddition. The tankfilter system showed an increase in the efficiency of removal of BOD and COD (from 64.68 to 83.99%, and 58.48% to 80.14%, respectively), pH maintenance (7.6) and reduction of sedimentable solids (from 1.38 to 0.23 mL/L).pt_BR
dc.format.extent1 recurso online : PDF.pt_BR
dc.format.mimetypeapplication/pdfpt_BR
dc.languagePortuguêspt_BR
dc.subjectEsgotos - Tratamentopt_BR
dc.subjectEfluente - Qualidadept_BR
dc.subjectSaneamentopt_BR
dc.subjectEngenharia Sanitáriapt_BR
dc.titleAvaliação de método de tratamento de efluentes urbanos utilizando autóctones microbianospt_BR
dc.typeDissertação Digitalpt_BR


Arquivos deste item

Thumbnail

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples