Mostrar registro simples

dc.contributor.authorHeuko, Everton Luizpt_BR
dc.contributor.otherKormann, Alessander Christopher Moralespt_BR
dc.contributor.otherUniversidade Federal do Paraná. Setor de Tecnologia. Programa de Pós-Graduação em Engenharia Civilpt_BR
dc.date.accessioned2021-07-12T21:11:28Z
dc.date.available2021-07-12T21:11:28Z
dc.date.issued2014pt_BR
dc.identifier.urihttps://hdl.handle.net/1884/37329
dc.descriptionOrientador : Prof. Dr. Alessander C. M. Kormannpt_BR
dc.descriptionDissertação (mestrado) - Universidade Federal do Paraná, Setor de Tecnologia, Programa de Pós-Graduação em Construção Civil. Defesa: Curitiba, 28/05/2014pt_BR
dc.descriptionInclui referênciaspt_BR
dc.descriptionArea de concentração : Geotecniapt_BR
dc.description.abstractResumo: A Usina Hidrelétrica Governador Pedro Viriato Parigot de Souza, constituída por uma barragem instrumentada de terra, está em operação desde a década de 1970. Apesar de estudos mostrarem que o maciço é estável, é importante o desenvolvimento de parâmetros de controle para o monitoramento e garantia da segurança da estrutura, dado que essa não era uma prática usual na época da construção do empreendimento. Portanto, o objetivo desse trabalho é estabelecer parâmetros de controle para a instrumentação da barragem através de análise estatística das séries históricas dos dados de instrumentação, e avaliação da estabilidade global do maciço considerando diversos cenários, relacionando-os com a instrumentação e fatores de segurança. As análises estatísticas dos dados foram realizadas para os medidores de recalque, piezômetros Casagrande, medidores de nível d'água e medidor de vazão, procurando, primeiramente, verificar a consistência dos dados e, na sequência, aplicar ferramentas estatísticas, como métodos de correlação de Pearson e box-plot, a fim de estabelecer os valores de controle. Os piezômetros e medidores de nível d'água foram associados aos níveis freáticos no interior do maciço, simulando diversos cenários e avaliando a estabilidade da estrutura através de ferramentas computacionais, correlacionando as análises e medidas dos instrumentos a fatores de segurança. Ao final das análises foi possível estabelecer os parâmetros de controle para a instrumentação, auxiliando na tomada de decisão sobre a segurança da barragem. Palavras-chave: Parâmetros de controle. Barragem de terra. Instrumentação.pt_BR
dc.description.abstractAbstract: The Governador Pedro Viriato Parigot de Souza Hydroelectric Power Plant, consisting of an instrumented earthen dam, is in operation since the 1970s. Although some studies show that the mass is stable, it is important to develop control parameters for monitoring and ensuring the safety of the structure, since this was not a practice at the time of construction of the project. Therefore, the aim of this work is to establish control parameters for the dam's instrumentation through statistical analysis of historical series of instrumentation data and to evaluate the overall stability of the body of the dam, considering several scenarios, relating them to the instrumentation and safety factors. Statistical analyzes of data were made for the settlement gauges (settlement measuring device) Casagrande piezometers, water level gauges and flow meter, first trying to verify data consistency and further applying statistical tools, with methods such as Pearson correlation and box-plot, in order to establish control values. The piezometers and water level gauges were associated with groundwater levels within the body of the dam, simulating various scenarios and evaluating the stability of the structure by computational tools, correlating analysis and measures of the instruments to safety factors. At the end of the analysis it was possible to establish the parameters for the control and instrumentation, helping in decision making about dam's safety. Key words: Control parameters. Earthen dam. Instrumentation.pt_BR
dc.format.extent135p. : il. algumas color., tabs.pt_BR
dc.format.mimetypeapplication/pdfpt_BR
dc.languagePortuguêspt_BR
dc.relationDisponível em formato digitalpt_BR
dc.subjectEngenharia Civilpt_BR
dc.subjectTesespt_BR
dc.subjectBarragens de terrapt_BR
dc.subjectUsinas hidreletricaspt_BR
dc.subjectBarragens e açudes - Medidas de segurançapt_BR
dc.titleDefinição de parâmetros de controle de uma barragem de terra através de análises estátiscas e avaliação de desempenho : estudo de caso da UHE Capivari-Cachoeirapt_BR
dc.typeDissertaçãopt_BR


Arquivos deste item

Thumbnail

Este item aparece na(s) seguinte(s) coleção(s)