• Login
    View Item 
    •   DSpace Home
    • BIBLIOTECA DIGITAL: Teses & Dissertações
    • 40001016002P6 Programa de Pós-Graduação em Ciências Geodésicas
    • Dissertações
    • View Item
    •   DSpace Home
    • BIBLIOTECA DIGITAL: Teses & Dissertações
    • 40001016002P6 Programa de Pós-Graduação em Ciências Geodésicas
    • Dissertações
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Determinação do erro ciclico em distanciometros eletronicos

    Thumbnail
    View/Open
    D - JUCILEI CORDINI.pdf (13.89Mb)
    Date
    1991
    Author
    Cordini, Jucilei
    Metadata
    Show full item record
    Subject
    Calibração
    Teses
    Levantamentos geologicos
    Geodesia
    xmlui.dri2xhtml.METS-1.0.item-type
    Dissertação
    Abstract
    Resumo: A calibração completa de um IMED envolve várias determinações de erros sistemáticos, cujos valores se modificam em função do uso constante e envelhecimento do equipamento. Parte desta calibração destina-se à determinação do erro cíclico em laboratório, normalmente conduzida sobre uma Linha de Teste. Este trabalho foi orientado no sentido de implementar e tornar operacional a Linha de Teste da UFPr , afim de adequá-la à seus propósitos e se transformar num instrumento útil para pós-graduandos, pesquisadores e usuários. Dentre os trabalhos executados e melhorias introduzidas à Linha de Teste, destaca-se a implantação de cinco sistemas refletores (espelhos) que possibilita a obtenção de distâncias superiores a 100 metros. Seis instrumentos de MED foram testados utilizando-se 03 e 05 espelhos normais, num total de 12 testes realizados; dois testes adicionais com espelhos frontais foram também realizados. Os resultados são apresentados e comprovam a eficiência do método e a praticidade do procedimento adotado.
     
    Abstract: The complete calibration of a EDMI implicate in many determinations of systematic errors, whose values modify as a function of the constant use and the aging of the equipment. Part of this calibration is for determination of the cyclic error in laboratory, normally carried out over a Test Line. This work was oriented in the meaning of to implement and at turning operational the Test Line of the UFPr, with the aim to adapt it to its purpose and at turning it a useful instrument to post-graduate, researchers and users. Among the work carried out and the improvement introduced to the Test Line, it must be distinguished the implantation of five reflector systems (mirrors) that make possible to obtain distances over a hundred meters. Six EDMI instruments were tested by the use of three and five normal mirrors making a total of twelve realized tests; two supplementary tests with frontal mirror were also realized. The results are show and they confirm the efficiency of the method used and the practicality of the procedure adopted.
     
    URI
    http://hdl.handle.net/1884/37187
    Collections
    • Dissertações [301]

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsxmlui.ArtifactBrowser.Navigation.browse_typeThis CollectionBy Issue DateAuthorsTitlesSubjectsxmlui.ArtifactBrowser.Navigation.browse_type

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV