Mostrar registro simples

dc.contributor.advisorBatista, Antonio Carlos, 1956-pt_BR
dc.contributor.otherSoares, Ronaldo Viana, 1943-pt_BR
dc.contributor.otherUniversidade Federal do Paraná. Setor de Ciências Agrárias. Programa de Pós-Graduação em Engenharia Florestalpt_BR
dc.creatorTetto, Alexandre Françapt_BR
dc.date.accessioned2022-11-25T16:25:53Z
dc.date.available2022-11-25T16:25:53Z
dc.date.issued2009pt_BR
dc.identifier.urihttps://hdl.handle.net/1884/21936
dc.descriptionOrientador : Prof. Dr. Antonio Carlos Batistapt_BR
dc.descriptionCo-orientador : Prof. Ph.D. Ronaldo Viana Soarespt_BR
dc.descriptionDissertação (mestrado) - Universidade Federal do Paraná, Setor de Ciências Agrárias, Programa de Pós-Graduação em Engenharia Florestal. Defesa: Curitiba, 24/09/2009pt_BR
dc.descriptionInclui bibliografiapt_BR
dc.descriptionÁrea de concentração : Conservação da naturezapt_BR
dc.description.abstractOs incêndios florestais têm impactado as unidades de conservação, sendo necessário o planejamento de ações que visem o seu controle. Esta pesquisa teve como objetivo propor uma metodologia para elaboração de planos de prevenção e combate em unidades de conservação, tomando por base a área de estudo. Definiu-se para este trabalho, em função da extensão, cobertura vegetal e existência de acompanhamento governamental, a Floresta Nacional (FLONA) de Irati, uma unidade de conservação de uso sustentável, localizada nos municípios de Fernandes Pinheiro e Teixeira Soares, no estado do Paraná. Para isso, foram identificados, quantificados e analisados os fatores de risco de incêndios florestais, formas de prevenção de incêndios florestais, bem como a estrutura de combate. Para o diagnóstico inicial e elaboração do zoneamento de risco de incêndios florestais (ZRIF) foram considerados os fatores do ambiente associados aos incêndios, tais como: cobertura vegetal, características topográficas, presença humana e zonas prioritárias, além das condições meteorológicas, o que possibilitou a determinação da estação normal de perigo de incêndios. Para essas análises, foram utilizados dados do Instituto Agronômico do Paraná, mapas, informações obtidas na FLONA e proposta de zoneamento ambiental existente. Posteriormente, foram obtidas informações sobre a estrutura física, máquinas, equipamentos e capital humano. Os resultados indicaram que a metodologia proposta deve seguir três etapas: fatores do ambiente associados aos incêndios florestais, prevenção e combate. A aplicação dessa metodologia é possível em função da sua adaptabilidade e operacionalidade, com a oportunidade de gerar um banco de dados, melhorando a gestão da unidade de conservação. Para a área de estudo, foi definida a estação normal de perigo de incêndios, bem como uma tendência de diminuição da umidade relativa, um aumento na temperatura do ar e na precipitação pluviométrica anual, para o período analisado. Com relação à quantificação do risco, observou-se que a cobertura vegetal apresenta 99,8% da sua área nos riscos alto e extremo de incêndio. A presença humana determina presença de risco em 7,6% da área e as zonas prioritárias totalizaram 19,0% da área com alto risco. Foi identificado que há necessidade de acompanhamento das atividades desenvolvidas no entorno da FLONA, sensibilização e envolvimento dos visitantes e da população do entorno, melhorando a prevenção de incêndios florestais. Para tanto, recomenda-se a formação de um banco de dados digital dos visitantes da unidade e da população do entorno, além de se estabelecer parcerias com instituições e organizações da região. Constatou-se um avanço, a partir de 2001, com o acompanhamento dado pelo IBAMA e, mais recentemente pelo Instituto Chico Mendes de Biodiversidade, em equipamentos, treinamento e capital humano. Os brigadistas possuem formação anual e têm disponibilidade de equipamentos para o combate. A unidade possui parceria com o Corpo de Bombeiros de Irati para capacitação, com estrutura para ampliação desses cursos, com potencial para servir como centro de treinamento para técnicos da área florestal e ambiental.pt_BR
dc.description.abstractWildfires have caused serious problems to some Brazilian Conservation Units, what requires strategic planning to prevent and control fire occurrences. The objective of this research was to propose a methodology to elaborate fire prevention and suppression projects, based on the Irati National Forest (Irati FLONA) conditions. This Conservation Unit was chosen due to its extension, vegetation covering, and management practices. The Irati FLONA is located in the Fernandes Pinheiro and Teixeira Soares counties, Paraná State, southern Brazil, at the coordinates 25° 25' south latitude, and 50o 36' west longitude. In the project elaboration, the forest fire risk factors, the prevention measures, and suppression structure were identified, quantified, and analyzed. For an initial diagnosis and the elaboration of a fire risk map, environment factors associated to fire occurrences, like vegetation covering, topography, human presence, and priority areas were considered. Meteorological conditions were used to establish the normal fire season. Data for these analyses were obtained from the Paraná Agricultural Institute, local maps, and the Irati FLONA records. Lately, information on physical structure, machinery, equipments, and manpower were obtained. The results indicated that the proposed methodology must follow three stages: environment factors associated to wildfires, fire prevention, and fire suppression. The normal fire season for the study area extended from May to September, with 73.8% of the occurrences, and a tendency on increasing the air temperature and the precipitation, and decreasing the relative humidity in the analyzed period were also observed. Regarding the risk evaluation, the results showed that 99.8% of the vegetation covering were classified as high and extreme fire risk. The human presence was responsible for fire risk in 7.6% of the area and the priority zones totalized 19.0% of the high risk area. It was also identified the necessity of accompaniment of the activities developed around the unit, and the conscientiousness raising of the visitors and neighbors, hence improving the prevention of human cause fires. It is recommended a data bank creation with information on visitors and neighbors, and the establishment of partnerships with regional institutions and organizations. It was observed an improvement, from 2001 on, in fire control equipments, training, and manpower, thanks to the actions of IBAMA and Chico Mendes Biodiversity Institute, government agencies responsible to the unit management. The fire crew members have had annual training programs, and equipments required to suppression activities. The unit has also a partnership with the local Fire Department for training the firefighters, with the potential to become, in the future, a forest and environment training center for technicians from all over the country. The application of the proposed methodology is possible due to its adaptability and operationally, besides the possibility of a data bank generation, that will constantly improve the Conservation Units management.pt_BR
dc.format.extent109f. : il. algumas color., mapas, grafs.pt_BR
dc.format.mimetypeapplication/pdfpt_BR
dc.languagePortuguêspt_BR
dc.relationDisponível em formato digitalpt_BR
dc.subjectTesespt_BR
dc.subjectIncêndios florestais - Prevenção e controlept_BR
dc.subjectÁreas de conservação de recursos naturais - Paranápt_BR
dc.subjectFloresta Nacional de Irati (PR)pt_BR
dc.subjectRecursos florestais e engenharia florestalpt_BR
dc.titleAvaliação do risco como subsídio para o planejamento da proteção contra incêndios florestais em unidades de conservação : estudo de caso da FLONA de Irati - PRpt_BR
dc.typeDissertaçãopt_BR


Arquivos deste item

Thumbnail

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples